From: Radiosurgery for classical trigeminal neuralgia: impact of the shot size on clinical outcome
5-mm cone | 6-mm cone | All | P value | |
---|---|---|---|---|
Dmax (mean) | 12.6 Gy | 21.3 Gy | 17.3 Gy | p < 0.001 |
Dmax (median) | 13.3 Gy | 20.4 Gy | 15.0 Gy | |
[Min–max] | [5.3–16.6] | [10.8–31.5] | [5.3–31.5] | |
V15 (mean) | 0.021 Gy | 0.108 Gy | 0.068 Gy | p < 0.001 |
[Min–max] | [0.000–0.057] | [0.004–0.231] | [0.000–0.231] | |
V27 (mean) | 0.002 Gy | 0.020 Gy | 0.012 Gy | p < 0.001 |
[Min–max] | [0.000–0.010] | [0.000–0.057] | [0–0.057] |